Products catalog

Alarm system board Trikdis FLEXi SP3, (2G+WIFI), 10 zones (20 ATZ), expandable up to 32, up to 8 keyboards

  • Alarm system board Trikdis FLEXi SP3, (2G+WIFI), 10 zones (20 ATZ), expandable up to 32, up to 8 keyboards

    Code: 200902
    Barcode: 868277046556275
    Price 169  VAT incl.
    (139 67  VAT excl.)
    Want another price? Suggest yours!
    In stock: 1 pcs

    Please check more precise delivery time when you choose your destination country in the Cart.

    0% VAT for orders from EU companies
    30 days money back guarantee
     10000+ successful deliveries

    Interested in this product? Contact us, we will offer alternative options.

    Manufacturer
    Sensor connection
    Wired
    Power source
    DC 16-24V
  • Reporting to the security company‘s central monitoring station (CMS):

    Event reporting either via the built-in WiFi module or cellular 2G/4G modem.
    Additional modules to send reports via Ethernet or VHF/UHF radio waves with chosen priority.
    Any CMS can receive reports, as long as they have TRIKDIS software/IP receiver or any other manufacturer’s IP receiver supporting SIA DC-09 IP protocol.
    Design based on two decades of experience in transmitting reports to main and backup central monitoring station receivers, which allows security companies to provide the highest level of protection to premises
    A setting for the necessity to send to CMS, to mandatorily send reports to CMS first, and only then to customers.
    Possibility to send event reports to CMS of two different security companies.
    Multitude number of message transmission channels and multiple transmission priority settings.
    Reporting to user:

    Via Protegus mobile app, which gives warnings about alarm system events using push and special sound notifications.
    Event reporting via SMS messages to 8 cellular numbers.
    Reporting about events using pre-recorded voice notifications (up to 8 cellular numbers).
    Remote control of selected premises’ protection mode (Arm/Disarm/Stay/Sleep).
    Remote control of connected devices (lighting system, automatic gates, ventilation, heating, watering systems, etc.).
    Remote temperature measuring.
    Inputs and outputs:

    10 I/O terminals, each one can be set as an input (IN) or output (OUT). Input (IN) types: ATZ, EOL, NC, NO. Different parameters of resistors can be used in EOL and ATZ type circuits. The number of inputs IN can be expanded to 32 by using keypads, iO-8, and iO-WL expander modules.
    The board has 2 dedicated outputs: the bell and the LED. The bell is to control the siren, and the LED is to control indicator lights. The number of outputs can be expanded to 16 by using iO-8 and iO-WL expander modules.
    Seven output operational settings. Each output can be assigned with an operational logic, a preset operation schedule, or qualities, for example, thermostat mode.
    One-wire data bus (“1-Wire”) is designated to connect temperature sensors (up to 8), a temperature and humidity sensor (1), or a key fob (“iButton”) reader.
    The GRN-YEL data bus is designated to connect 8 keypads of the same type.
    The RS485 data bus connects iO series expander modules: RF-SH radio wave wireless sensor transceiver, E485 Ethernet module, T16 VHF, or UHF radio wave transmitter.
    Control of alarm system

    4-digit long control codes (40 in total), which may be used as a coercion code as well. In such a scenario, entering the user code will disarm the alarm, yet a special report will be sent to the CMS indicating that the alarm was disarmed as a result of coercion.
    Control using keypads: SK232LED, Paradox K636, K10H(V) K32+LED, K32LED, K35, Crow keypad CR16, CR-LCD, CZ-Dallas electronic (“iButton”) key reader, TM17 electronic key reader, RFID reader (Wiegand 26/34).
    Remote control via Protegus mobile app, phone call, or SMS.
    Simple installation:

    Multiple sizes of SP3 mounting kits that include a decorative white metal housing with a built-in step-down transformer or impulse power supply.
    Default SP3 operational settings are based on many years of experience. That allows us to install the system in 7 out of 10 small and medium-sized premises without the need to change the default settings.
    The SP3 control panel allows us to replace the previous panel without changing the resistors in each wired sensor.
    Settings can be saved as a file to be used later.
    Device configuration via USB cable or remotely by using TrikdisConfig
    Remote connection via TrikdisConfig software allows not only altering SP3 parameters but monitoring the operation of the panel as well.
    Two access levels for parameter settings: installer and administrator. 


    Parameter 
    Description 
    Power supply voltage[AC / DC]  16 V AC or 16-24 V DC, 2,5 A 
    Current consumption  Up to 50 mA (stand-by),
    Up to 200 mA (short-term, while sending) 
    Backup power source [BAT]  12 V lead – acid battery, 4 Ah/7 Ah 
    Battery charge current  Up to 500 mA 
    Power voltage and current for external devices [AUX]  12 V DC, up to 1 A 
    Siren output [BELL]   1 A 
    Output [LED]  0,1 A 
    PGM output  0,1 A 
    WiFi module   Yes, built-in 
    WiFi frequency, protocol, encryption type  2,4 GHz, 802.11 b/g/n, WPA, WPA2, WPA mixed 
    WiFi network configuration type   DHCP or manual 
    SIM card  1, NANO size 
    GSM/GPRS modem frequencies  850 / 900 / 1800 / 1900 MHz 
    4G modem frequencies  800 / 850 / 900 / 1900 / 2100 MHz 
    Report transmission directions 

    To main and backup receivers of 2 different security companies;
    To Protegus cloud, to iOS/Android Protegus mobile apps;

    To 8 mobile phones via SMS messages.

    Calls 8 mobile phones. If a user answers the call, announces what happened using voice. 

    Event reporting transmission channels  GPRS or 4G, WiFi, LAN (with module E485), SMS, Voice call, VHF/UHF radio waves (with transmitter T16) 
    Protocols for connection to CMS  TCP / IP or UDP / IP, or SMS 
    Event encoding  Contact ID codes 
    Report encryption  TRK AES 128, SIA IP AES 128 
    Internal clock  Yes 
    Buffer memory capacity  60 events 
    Events log memory  Up to 1000 events. Oldest entries deleted automatically. 
    User codes  40 
    Duress code   Two code entry methods can be chosen during programming 
    Dual purpose terminals [I/O]  10; IN or OUT function selected during programming. When IN is selected, available types: NC, NO, EOL, EOL_T, ATZ, ATZ_T. When OUT is selected, the terminal becomes open collector (OC) type with up to 100 mA current 
    No. of partitions  8
    No. of zones   10 (20 zones if using ATZ), (can be expanded to 32 zones using expanders)
    No. of PGM outputs  2 (can be 12 if IO terminals are set as outputs. Can be expanded to 16 outputs with expanders) 
    Max. number of connected keypads  8
    Supported keypads 

    Protegus SK232 LED W
    FLEXi SK232 LCD

    Paradox K636

    Paradox K10H(V)

    Paradox K32 LED

    Paradox K32+ LED

    Paradox K32LCD+

    Paradox K35

    Paradox TM50

    Paradox TM70

    Crow CR16

    Crow CR-LCD 

    Max. number of RFID readers (Wiegand 26/34)  2
    1-Wire data bus length [1 WIRE]   Up to 30 m 
    Compatible temperature sensors  Maxim®/Dallas® DS18S20, DS18B20; AM2301 series 
    Max. number of temperature sensors connected to 1-Wire data bus  8 (Dallas) or 1 (if an AM2301 series sensor is used) 
    Compatible electronic (iButton) keys [1 WIRE]   Maxim®/Dallas® DS1990A 
    Max. no. of electronic (iButton) keys   40 
    RS485 data bus length   Up to 100 m 
    Max. no. of devices connected to RS485 data bus 
    Supported modules 

     iO-8 – expander module;
    iO – expander module;

    iO-MOD – iO-WL radio wave transceiver;

    iO-WL – wireless expander module;

    RF-SH – radio wave receiver for wireless sensors;

    E485 – module for connecting to Ethernet network;

    TM17 – iButton key reader;

    CZ-Dallas – iButton key reader;

    T16 – VHF or UHF radio wave transmitter;

    RFID reader. 

    Operating environment  Temperature from -10 °C to +50 °C, relative humidity 80% at +20°C, no condensation. 
    Dimensions of the control panel  117x79x25 mm 
    Weight  0,1 kg